High Voltage 384V Solar Charge Controller 100A 150A 200A MPPT Solar Charger Controller 360V
Technical Specifications of Solar Charger Controller:
Voltage level |
GSM48 |
GSM96 |
GSM192 |
GSM220 |
GSM240 |
||
Rated voltage (VDC) |
48 |
96 |
192 |
216 |
240 |
||
Over voltage value(VDC) |
62.0 |
124.0 |
248.0 |
279.0 |
310.0 |
||
Over voltage recovery value(VDC) |
60.0 |
120.0 |
240.0 |
270.0 |
300.0 |
||
Float charge Voltage(VDC) |
Settable |
54.0 |
108.0 |
216.0 |
243.0 |
270.0 |
|
Bulk charge Voltage(VDC) |
|
56.8 |
113.6 |
227.2 |
255.6 |
284.0 |
|
Maximum charging current (A) |
60/120/180/240 |
50/100/150/200 |
|||||
No of Input modules |
1/2/3/4 |
1/2/3/4 |
|||||
Charging Mode |
Three-stage: constant current(MPPT),bulk charge, float charge |
||||||
Rated input power (kWp) |
3.4/6.8/ 10.2/13.6 |
5.7/11.4/ 17.1/22.8 |
11.4/22.8/ 34.2/45.6 |
12.8/25.6/ 38.4/51.2 |
14.2/28.4/ 42.6/56.8 |
||
Start work voltage(VDC) |
60 |
120 |
240 |
270 |
300 |
||
MPPTvoltage range(VDC) |
50-150 |
110-280 |
230-450 |
260-450 |
290-450 |
||
Maximum input voltage (VDC) |
170 |
300 |
480 |
||||
Maximum efficiency |
>98% |
Model No |
360V-100A |
360V-150A |
360V-200A |
||
Rated voltage (VDC) |
360/384 |
||||
Charging Mode |
Three-stage: CC, CV, CF |
||||
Float charge Voltage(VDC) |
405 |
||||
Bulk charge voltage (VDC) |
426 |
||||
Over voltage value (VDC) |
465 |
||||
Over voltage recovery value (VDC) |
450 |
||||
Rated charging current (A) |
100 |
150 |
200 |
||
Input modules |
2 |
3 |
4 |
||
Max. open circuit voltage (VDC) |
720 |
||||
Recommended work voltage (VDC) |
480 |
||||
Start work voltage(VDC) |
420 |
||||
Noise (dB) |
<50 |
||||
Degree of protection |
IP20 |
||||
Display |
LCD+LED |
||||
Communication |
RS485 (optional) |
||||
Working temperature |
-10~+50℃ |
||||
Relative humidity |
0 to 95% (non-condensing) |
||||
Altitude (m) |
≤5000m, (capacity decreased as GB/ 3859.2 when altitude higher than 1000m) |
||||
Dimensions (W × H × D mm) |
168*550*417 |
440*1000*450 |
|||
Net Weight (Kg) |
13 |
40 |
42 |
||
Protection |
PV array reverse polarity protection; reverse battery protection; nighttime anti-charge protection; battery overcharge protection, output overload protection, over temperature protection etc. |
Above information is just for reference, no inform if there is any change. Special voltage can be customized.
Big OFF GRID Solar Power System Connection:
Greensun OFF GRID SOLAR Power System with Solar Controller
Greensun Solar can provide 48V/96V/192V/240V/360V/384V Solar Charger Controller for Off Grid Solar System.
OEM,ODM service accpetable
Solusi satu atap untuk sistem tenaga surya. Untuk informasi lebih lanjut, jangan ragu untuk menghubungi tim kami
Email: info@greensunpv.com
Wechat & Whatsapp: +86 158 5510194
Skype: greensun.solar@outlook.com